The Cefas G6A is a new product that includes a 3 axis accelerometer ±2g in addition to the usual pressure and temperature sensors. This tag also has a larger battery to support the logging of data at up to 30Hz, which offers a combination of longer life and larger memory capacity. The tag is capable of taking up to 40 million readings from its sensors over the life of the battery.
DST users want greater programming flexibility, so a key feature of the G6A is its independent sensor settings. Repeat Logging allows users to configure short bursts of data logging over an extended period of time.
If your research involves studying diving birds and mammals, you will be interested in our Dive Switch and Fast Logging Rate. The dive switch allows the Fast Logging Rate to be activated when the animal enters the water so that dive profiles can be measured.
Robustness and reliability of the Cefas tag technology comes as standard.
| Specification | Cefas G6A 16 MB / 40 MB |
|
|---|---|---|
| Max Dimensions Length x Width x Height |
40 mm x 28 mm x 16.3 mm | |
| Tag Body Diameter | N/A | |
| Weight in Air | 7.3 g | |
| Weight in Seawater | 2.3 g | |
| Depth Sensors 1 | 100, 200, 500, 1000, 2000m | |
| Absolute Max Depth | 1.5x pressure sensor rating | |
| Operating Temperature | -20°C to 60°C | |
| Absolute Temp Range | -30°C to 60°C | |
| Maximum number of readings at 8 bit resolution |
16.711 M | 41.88 M |
| Multiple 15 day memory fill | 7 / 3 | |
| Rate of logging | Up to 1 hour at 1 second resolution Up to 18 hours at 1 minute resolution |
|
| Accelerometer range | +/-2 g | |
| Accelerometer resolution | 18 mg | |
| Optional Dive Logging / Water Switch | 30Hz; 25Hz; 20Hz; 15Hz; 10Hz; 7Hz; 5Hz; 4Hz; 2Hz | |
| Accelerometer rate | 30Hz; 25Hz; 20Hz; 15Hz; 10Hz; 7Hz; 5Hz; 4Hz; 2Hz | |
|
||
| Specification | Cefas G6A 16 MB / 40 MB |
|
| Physical Parameters | ||
| Casing | Epoxy Resin / Urethane | |
| Real Time Clock | ||
| Temperature Compensated | Yes, 2°C to 34°C User settable |
|
| Memory | ||
| Type Flash | 16MB | 40MB |
| Time series data points4 | ||
| at 8 bit resolution | 16.711 M | 41.88 M |
| at 10 bit resolution | 13.369 M | 33.504 M |
| at 12 bit resolution | 11.14 M | 27.92 M |
| Delayed Start of Logging | Yes | |
| Data retention | 20 years | |
| Summary Log | Daily record of max / min parameters | |
| Other | ||
| Battery Chemistry | Lithium Manganese Dioxide | |
| Communication | Direct Contact | |
| Communications rate | 115.2 k baud | |
| Depth Sensing | ||
| Accuracy | ±1% Full Scale at 12 bit ADC | |
| Resolution | 100 m sensor Better than 4 cm 200 m sensor Better than 8 cm 500 m sensor Better than 15 cm 1000 m sensor Better than 30 cm 2000 m sensor Better than 60 cm |
|
| Temperature Compensated2 | Yes, 2°C to 34°C | |
| Maximum depth before pressure sensor failure | 1.5 X Full Scale | `|
| Temp Sensing | ||
| Accuracy | ±0.1°C at 12 bit ADC Range3 2°C to 34°C | |
| Resolution | 0.03125°C | |
| Response Time 3 | 15 seconds / 60 seconds | |
| Required Peripherals | ||
| Reader | Connected via serial port or USB serial adaptor | |
| Data Output | CSV format (MS Excel etc.) | |
| Software | G5 Host – Windows XP (32bit), Windows Vista (32bit), Windows 7 (32bit and 64 bit) | |
Notes
Specifications mentioned in this publication are subject to change without notice. This publication supersedes and replaces all information previously supplied.
Matthew Eagle
Cefas Technology Limited (CTL)
Tel: +44 (0) 1502 524308
Fax: +44 (0) 1502 527769