CTL

G6 DST

G6 Data Storage Tag

Overview

The Cefas G6 is based upon the tried and tested Cefas G5, logging pressure and temperature, but it offers the additional benefits of a longer life and much larger memory capacity. The tag is capable of taking up to 40 million readings from its pressure or temperature sensors over the life of the battery.

DST users want greater programming flexibility, so key features of the G6 are its independent pressure and temperature settings. Repeat Logging allows users to configure short bursts of data logging over an extended period of time.

If your research involves studying diving birds and mammals, you will be interested in our Dive Switch and Fast Logging Rate. The dive switch allows the Fast Logging Rate to be activated when the animal enters the water so that dive profiles can be measured.

  • Fast Logging at rates at up to 10Hz
  • Fast Logging Rate activated by entry into water
  • deactivated by removal from water / return to surface
  • operates in fresh water and seawater

Robustness and reliability of the Cefas tag technology comes as standard.

Key Features

Specification Cefas G6 16MB Cefas G6 40MB
Max Dimensions
Length x Width x Height
40mm x 28mm x 15mm
Weight in Air 7.3g
Weight in Seawater 2.3g
Depth Sensors 1 100, 200, 500, 1000, 2000m
Absolute Max Depth 1.5x pressure sensor rating
Operating Temperature -10°C to 60°C
Absolute Temp Range -30°C to 60°C
Maximum number of readings
at 8 bit resolution
16.711M 41.88M
Battery Life 2 5 years
Multiple 15 day memory fill 8 4
Rate of logging Up to 1 hour at 1 second resolution
Up to 18 hours at 1 minute resolution
Dive Logging / Water Switch 10Hz; 7Hz; 5Hz; 4Hz; 2Hz


Additional Specifications 

Specification Cefas G6 16MB Cefas G6 40MB
Physical Parameters  
Casing Epoxy resin / Urethane
Real Time Clock  
Temperature Compensated Yes, 2°C to 34°C
User settable
Memory  
Type Flash 16MB 40MB
Time series data points 5  
at 8 bit resolution 16.711M 41.88M
at 10 bit resolution 13.369M 33.504M
at 12 bit resolution 11.141M 27.92M
Delayed Start of Logging Yes
Data retention 20 years
Summary Log Daily record of max / min parameters
Communication rate 115.2k baud
Other  
Battery Chemistry Lithium Manganese Dioxide
Communication Direct Contact
Depth Sensing    
Accuracy ±1% Full Scale at 12 bit ADC
Resolution 100 m sensor Better than 4 cm
200 m sensor Better than 8 cm
500 m sensor Better than 15 cm
1000 m sensor Better than 30 cm
2000 m sensor Better than 60 cm
Temperature Compensated3 Yes, 2°C to 34°C
Maximum depth before pressure sensor failure 1.5 X Full Scale
Temp Sensing  
Accuracy ±0.1°C at 12 bit ADC Range 3  2°C to 34°C
Resolution 0.03125°C
Response Time 4 15 seconds / 60 seconds
Required Peripherals  
Reader Connected via serial port or USB serial adaptor
Data Output CSV format (MS Excel etc.)
Software G5 Host – Windows XP (32bit), Windows Vista (32bit), Windows 7 (32bit and 64 bit)

Notes

  1. Optional depth sensing ranges available
  2. Under normal operating conditions and single memory fill. Multiple deployments may significantly affect the tag life
  3. Accuracy degrades outside this range.
  4. Typical time to reach 66% / 90% of step from 5 to 30 degrees

Specifications mentioned in this publication are subject to change without notice. This publication supersedes and replaces all information previously supplied.

Quote Me

Pressure:

Quantity:

Additional information:

Name:

Email:

Send Enquiry

Contact Us

Matthew Eagle
Cefas Technology Limited (CTL)

Tel: +44 (0) 1502 524308

Fax: +44 (0) 1502 527769

info@cefastechnology.co.uk