Google
the web www.cefastechnology.co.uk 
 
 
  Home     
You are in: Data Storage Tags - G5 DST -G5 Tag Specification

 

G5 Tag Specification

Key Features

Specification Cefas G5 Standard
1 MB / 2 MB
Cefas G5 Long Life
1 MB / 2 MB
Diameter 8 mm 11.5 mm
Length 31 mm 35.5 mm
Weight in Air 2.7 g 5.7 g
Weight in Water 1.3 g 2.25 g
Depths Sensors1 100, 200, 500, 1000, 2000 m
Absolute Max Depth 3000 m
Operating Temperature -2°C to 40°C
Absolute Temp Range -10°C to 70°C
Maximum number of readings at 8 bit resolution 1.036M / 2.031M
Battery Life2 10 months 24 months
Multiple 30 day memory fill 3 10
Rate of logging Up to 1 hour at 1 second resolution
Up to 18 hours at 1 minute resolution
Optional Dive Logging / Water Switch 10 Hz; 5 Hz; 4 Hz; 2 Hz

 
Additional Specifications
 

Specification Cefas G5 Standard
1 MB / 2 MB
Cefas G5 Long Life
1 MB / 2 MB
Physical Parameters    
Casing Acrylic / Urethane
Real Time Clock  
Temperature Compensated Yes 2°C to 34°C, User settable
Memory    
Type Flash 1MB / 2 MB
Time series data points  
at 8 bit resolution 1.036 M / 2.031M
at 10 bit resolution 832 k / 1.625 M
at 12 bit resolution 693 k / 1.354 M 
Delayed start of logging Yes
Data retention 10 years
Summary Log Daily record of max/min parameters
Communications rate 115.2k baud
Other    
Battery Chemistry Silver
Communication Direct Contact
Depth Sensing      
Accuracy3 ±1% Full Scale at 12 bit ADC
Resolution 100 m sensor Better than 4 cm
200 m sensor Better than 8 cm
500 m sensor Better than 15 cm
1000 m better than 30 cm
2000 m sensor Better than 60 cm
Temperature Compensated3 Yes 2°C to 34°C
Maximum depth before pressure sensor failure 1.5 X Full Scale
Temp Sensing    
Accuracy ±0.1°C at 12 bit ADC Range3 -2°C to 34°C
Resolution 0.03125°C
Response Time 4 28 sec
Required Peripherals    
Reader Connected via serial port or USB serial adaptor
Data Output CSV format (MS Excel etc.)
Software G5 Host – Windows OS

Notes

  1. Optional depth sensing ranges available
  2. Under normal operating conditions and a single 1 MB memory fill. Multiple deployments may significantly affect the tag life
  3. Accuracy degrades outside this range.
  4. Typical time to reach 66% of step from 5 to 30 degrees

Specifications mentioned in this publication are subject to change without notice. This publication supersedes and replaces all information previously supplied.